Description
- Place of Origin : China
- Brand Name : OEM brand
- Model Number : HRV2-36T
- Power : 1 Phase 40A
- Voltage : 220V 230V, 1Phase 220V 230V
- type : Adjustable
- Contact : 40A 1NO
- Width : 36mm
40A 220V 230V Adjustable auto recovery reset reconnect Din rail Over and Under voltage Protector protective device relay
Applications:
Used for over voltage and under voltage protection in home and villa single-phase control system,.
Features:
– Adjustable
– Controls its own supply voltage (True RMS measurement).
– Voltage value and delay time be set via switch knob.
– Value with auto restart and self-resetting functions.
– Voltage measurement accuracy <1%.
– Control status is indicated by a LED.
– The relays are designed for clip-on mounting on rail.
Technical Parameters:
Rated supply voltage | AC 220~240V |
Rated supply frequency | 50/60Hz +-10% |
Max. current output | 40A |
Overvoltage operating value | 225V~265V (knob adjustment) |
Overvoltage Hysteresis | Overvoltage operating value *(1-3%) |
Undervoltage operating value | 165V~215V (knob adjustment) |
Undervoltage Hysteresis | Undervoltage operating value *(1+3%) |
Tripping time delay | 0.1s~10s(knob adjustment) |
Power-on delay time | 0.3s~30s(knob adjustment) |
Reset delay time | 0.3s~30s(knob adjustment) |
Measurement error | <=1% |
Delay error | +-10%+0.1s |
Konb setting accuracy | +-2V |
Rated insulation voltage | 415V |
IP degree of protection | IP20 |
Pollution degree | 3 |
Electrical durability | 100000 cycles |
Mechanical durability | 1000000 cycles |
Height above sea level | <=2000m |
Operation temperature | -5…40℃ |
Relative humidity | <=50%(40℃) |
Panel Description:
Function Diagrams:
Overall Dimension:
Wiring Diagram:
Typical Application:
]
Operation Instruction:
1.Wire the protector according to the indicator IN and OUT directive.
2.When the protector is with normal supply voltage, yellow R/T indicator stays light-on, relay implements output action; otherwise protector showsfault while relay gets disconnected.
3.In case supply voltage goes over the set voltage operating value, yellow R/Tindicator flickers and red U > indicator light-on. When fault time islonger than the set delay time, output relay gets disconnected, R/T indicator light-off.And if supply voltage is lower than undervoltage operating value, yellow R/Tindicator flickers and red U< light-on. Also when fault time is longer than the set delay time, output relay gets disconnected, R/T indicator light-off.
4.When overvoltage fault protection is on and supply voltage is lower than overvoltage reset value, output relay actuates and R/T indicator light-on;when overvoltage fault protection is on and supply voltage ishigher thanundervoltage reset value, output relay actuates and R/T indicator light-on.
5.When supply voltage is lower than 150V, protector activates right away with no action delay;meanwhile,yellow R/T indicator light-off, red U< indicator light-on,and output relay gets disconnected.
6.Wiring terminal: N represents Neutral Line, L represents Live Line, please donot mix up.
7.To avoid heating of contact from heavy current, please make sure the screw nail on the wiring terminal is tightened so as to prevent protector burning-up or other induced disaster.