Chint original NA8 NA8G series Air Circuit Breaker NA8G-1600 NA8G-2500 NA8G-3200 NA8G-4000 NA8G-6300 CHNT ACB

Place of Origin : China Brand Name : Chint Model Number : NA8G Breaking Capacity : 25kA – 120kA Rated Voltage : 415V, 690V Rated Current : 400A – 6300A Number of Pole : 3P, 4P Protection : Other Type : Air Chint original NA8 NA8G series Air Circuit Breaker NA8G-1600 NA8G-2500 NA8G-3200 NA8G-4000 NA8G-6300…

SKU: 1600083363909
Category:

Description

  • Place of Origin : China
  • Brand Name : Chint
  • Model Number : NA8G
  • Breaking Capacity : 25kA – 120kA
  • Rated Voltage : 415V, 690V
  • Rated Current : 400A – 6300A
  • Number of Pole : 3P, 4P
  • Protection : Other
  • Type : Air

Chint original NA8 NA8G series Air Circuit Breaker NA8G-1600 NA8G-2500 NA8G-3200 NA8G-4000 NA8G-6300 CHNT ACB

 

1.1 Application scope
With rated current from 200A to 6300A, and rated service voltage of AC 415V or 690V, NA8G series air circuit breaker is mainly used in the distribution network with the circuit of AC 50HZ/60HZ to distribute electric energy and protect circuits and electric equipment against over-load, under-voltage, short- circuit, single-phase earthing fault.

Having art-oriented appearance, high breaking capacity, zero arcover and varities of intellectualized protection functions, the
breaker can be used for selective protection with accurate action, no unnecessary power cut, and better power supply reliability.

That breaker can be widely used for power stations, factories, mines and modern tall buildings, especially the distribution
system in the intelligent building, and also widely used in green projects such as wind and solar power generation.

1.2 Standard : IEC/EN 60947-2.

 

2.1 Temperature condition:
      -5℃~40℃; the average value within 24h shall not exceed
      +35℃ (special situation excluded);
2.2 Altitude:≤2000m;
2.3 Pollution grade: Grade 3;
2.4 Air conditions:
      At mounting site, relative humidity not exceed 50% at the max temperature of +40℃, higher relative humidity is allowable
      under lower temperature, RH could be 90% at +20℃, special measures should be taken to occurrence of dews;
2.5 Note: Without the intelligent controller, the breaker functions as a switch-disconnector.

Chint original NA8 NA8G series Air Circuit Breaker NA8G-1600 NA8G-2500 NA8G-3200 NA8G-4000 NA8G-6300 CHNT ACBChint original NA8 NA8G series Air Circuit Breaker NA8G-1600 NA8G-2500 NA8G-3200 NA8G-4000 NA8G-6300 CHNT ACBChint original NA8 NA8G series Air Circuit Breaker NA8G-1600 NA8G-2500 NA8G-3200 NA8G-4000 NA8G-6300 CHNT ACBChint original NA8 NA8G series Air Circuit Breaker NA8G-1600 NA8G-2500 NA8G-3200 NA8G-4000 NA8G-6300 CHNT ACB