HRV2-36T 40A 220V 230V Adjustable auto recovery reset reconnect Din rail Over Under Voltage Protector protective device

Place of Origin : China Brand Name : OEM brand Model Number : HRV2-36T Power : 1 Phase 40A Voltage : 220V 230V, 1Phase 220V 230V type : Adjustable Contact : 40A 1NO Width : 36mm 40A 220V 230V Adjustable auto recovery reset reconnect Din rail Over and Under voltage Protector protective device relay  …

SKU: 62251701873
Category:

Description

  • Place of Origin : China
  • Brand Name : OEM brand
  • Model Number : HRV2-36T
  • Power : 1 Phase 40A
  • Voltage : 220V 230V, 1Phase 220V 230V
  • type : Adjustable
  • Contact : 40A 1NO
  • Width : 36mm

40A 220V 230V Adjustable auto recovery reset reconnect Din rail Over and Under voltage Protector protective device relay

 

Applications:
Used for over voltage and under voltage protection in home and villa single-phase control system,.

 

Features:

Adjustable
– Controls its own supply voltage (True RMS measurement).
– Voltage value and delay time be set via switch knob.
– Value with auto restart and self-resetting functions.
– Voltage measurement accuracy <1%.
– Control status is indicated by a LED.

– The relays are designed for clip-on mounting on rail.

 

Technical Parameters:

Rated supply voltage  AC 220~240V
Rated supply frequency  50/60Hz +-10%
Max. current output  40A
Overvoltage operating value  225V~265V (knob adjustment)
Overvoltage Hysteresis  Overvoltage operating value *(1-3%)
Undervoltage operating value  165V~215V (knob adjustment)
Undervoltage Hysteresis  Undervoltage operating value *(1+3%)
Tripping time delay  0.1s~10s(knob adjustment)
Power-on delay time  0.3s~30s(knob adjustment)
Reset delay time  0.3s~30s(knob adjustment)
Measurement error  <=1%
Delay error  +-10%+0.1s
Konb setting accuracy  +-2V
Rated insulation voltage  415V
IP degree of protection  IP20
Pollution degree  3
Electrical durability  100000 cycles
Mechanical durability  1000000 cycles
Height above sea level  <=2000m
Operation temperature  -5…40℃
Relative humidity  <=50%(40℃)

 

Panel Description:
HRV2-36T 40A 220V 230V Adjustable auto recovery reset reconnect Din rail Over Under Voltage Protector protective device

 

Function Diagrams:

HRV2-36T 40A 220V 230V Adjustable auto recovery reset reconnect Din rail Over Under Voltage Protector protective device

 

Overall Dimension:

HRV2-36T 40A 220V 230V Adjustable auto recovery reset reconnect Din rail Over Under Voltage Protector protective device

 

Wiring Diagram:

HRV2-36T 40A 220V 230V Adjustable auto recovery reset reconnect Din rail Over Under Voltage Protector protective device

 

Typical Application:

HRV2-36T 40A 220V 230V Adjustable auto recovery reset reconnect Din rail Over Under Voltage Protector protective device]

 

Operation Instruction:

  1.Wire the protector according to the indicator IN and OUT directive.

  2.When the protector is with normal supply voltage, yellow R/T indicator stays light-on, relay implements output action; otherwise protector showsfault while relay gets disconnected.

  3.In case supply voltage goes over the set voltage operating value, yellow R/Tindicator flickers and red U > indicator light-on. When fault time islonger than the set delay time, output relay gets disconnected, R/T indicator light-off.And if supply voltage is lower than undervoltage operating value, yellow R/Tindicator flickers and red U< light-on. Also when fault time is longer than the set delay time, output relay gets disconnected, R/T indicator light-off.

  4.When overvoltage fault protection is on and supply voltage is lower than overvoltage reset value, output relay actuates and R/T indicator light-on;when overvoltage fault protection is on and supply voltage ishigher thanundervoltage reset value, output relay actuates and R/T indicator light-on.

  5.When supply voltage is lower than 150V, protector activates right away with no action delay;meanwhile,yellow R/T indicator light-off, red U< indicator  light-on,and output relay gets disconnected.

  6.Wiring terminal: N represents Neutral Line, L represents Live Line, please donot mix up.

  7.To avoid heating of contact from heavy current, please make sure the screw nail on the wiring terminal is tightened so as to prevent protector burning-up or other induced disaster.